Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Breast Cancer Res ; 22(1): 57, 2020 05 28.
Artigo em Inglês | MEDLINE | ID: mdl-32466777

RESUMO

BACKGROUND: For breast cancer patients undergoing neoadjuvant chemotherapy (NAC), pathologic complete response (pCR; no invasive or in situ) cannot be assessed non-invasively so all patients undergo surgery. The aim of our study was to develop and validate a radiomics classifier that classifies breast cancer pCR post-NAC on MRI prior to surgery. METHODS: This retrospective study included women treated with NAC for breast cancer from 2014 to 2016 with (1) pre- and post-NAC breast MRI and (2) post-NAC surgical pathology report assessing response. Automated radiomics analysis of pre- and post-NAC breast MRI involved image segmentation, radiomics feature extraction, feature pre-filtering, and classifier building through recursive feature elimination random forest (RFE-RF) machine learning. The RFE-RF classifier was trained with nested five-fold cross-validation using (a) radiomics only (model 1) and (b) radiomics and molecular subtype (model 2). Class imbalance was addressed using the synthetic minority oversampling technique. RESULTS: Two hundred seventy-three women with 278 invasive breast cancers were included; the training set consisted of 222 cancers (61 pCR, 161 no-pCR; mean age 51.8 years, SD 11.8), and the independent test set consisted of 56 cancers (13 pCR, 43 no-pCR; mean age 51.3 years, SD 11.8). There was no significant difference in pCR or molecular subtype between the training and test sets. Model 1 achieved a cross-validation AUROC of 0.72 (95% CI 0.64, 0.79) and a similarly accurate (P = 0.1) AUROC of 0.83 (95% CI 0.71, 0.94) in both the training and test sets. Model 2 achieved a cross-validation AUROC of 0.80 (95% CI 0.72, 0.87) and a similar (P = 0.9) AUROC of 0.78 (95% CI 0.62, 0.94) in both the training and test sets. CONCLUSIONS: This study validated a radiomics classifier combining radiomics with molecular subtypes that accurately classifies pCR on MRI post-NAC.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Aprendizado de Máquina , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/tratamento farmacológico , Carcinoma Ductal de Mama/patologia , Carcinoma Ductal de Mama/cirurgia , Carcinoma Lobular/diagnóstico por imagem , Carcinoma Lobular/tratamento farmacológico , Carcinoma Lobular/patologia , Carcinoma Lobular/cirurgia , Feminino , Seguimentos , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Terapia Neoadjuvante , Prognóstico , Curva ROC , Estudos Retrospectivos
2.
Breast Cancer Res ; 22(1): 58, 2020 05 28.
Artigo em Inglês | MEDLINE | ID: mdl-32466799

RESUMO

BACKGROUND: Ultrafast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI)-derived kinetic parameters have demonstrated at least equivalent accuracy to standard DCE-MRI in differentiating malignant from benign breast lesions. However, it is unclear if they have any efficacy as prognostic imaging markers. The aim of this study was to investigate the relationship between ultrafast DCE-MRI-derived kinetic parameters and breast cancer characteristics. METHODS: Consecutive breast MRI examinations between February 2017 and January 2018 were retrospectively reviewed to determine those examinations that meet the following inclusion criteria: (1) BI-RADS 4-6 MRI performed on a 3T scanner with a 16-channel breast coil and (2) a hybrid clinical protocol with 15 phases of ultrafast DCE-MRI (temporal resolution of 2.7-4.6 s) followed by early and delayed phases of standard DCE-MRI. The study included 125 examinations with 142 biopsy-proven breast cancer lesions. Ultrafast DCE-MRI-derived kinetic parameters (maximum slope [MS] and bolus arrival time [BAT]) were calculated for the entire volume of each lesion. Comparisons of these parameters between different cancer characteristics were made using generalized estimating equations, accounting for the presence of multiple lesions per patient. All comparisons were exploratory and adjustment for multiple comparisons was not performed; P values < 0.05 were considered statistically significant. RESULTS: Significantly larger MS and shorter BAT were observed for invasive carcinoma than ductal carcinoma in situ (DCIS) (P < 0.001 and P = 0.008, respectively). Significantly shorter BAT was observed for invasive carcinomas with more aggressive characteristics than those with less aggressive characteristics: grade 3 vs. grades 1-2 (P = 0.025), invasive ductal carcinoma vs. invasive lobular carcinoma (P = 0.002), and triple negative or HER2 type vs. luminal type (P < 0.001). CONCLUSIONS: Ultrafast DCE-MRI-derived parameters showed a strong relationship with some breast cancer characteristics, especially histopathology and molecular subtype.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Adulto , Idoso , Neoplasias da Mama/patologia , Neoplasias da Mama/terapia , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/patologia , Carcinoma Ductal de Mama/terapia , Carcinoma Lobular/diagnóstico por imagem , Carcinoma Lobular/patologia , Carcinoma Lobular/terapia , Meios de Contraste , Feminino , Seguimentos , Humanos , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Adulto Jovem
3.
Front Oncol ; 10: 595820, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33614481

RESUMO

PURPOSE: Breast MRI background parenchymal enhancement (BPE) can potentially serve as a prognostic marker, by possible correlation with molecular subtype. Oncotype Dx, a gene assay, is a prognostic and predictive surrogate for tumor aggressiveness and treatment response. The purpose of this study was to investigate the association between contralateral non-tumor breast magnetic resonance imaging (MRI) background parenchymal enhancement and tumor oncotype score. METHODS: In this retrospective study, patients with ER+ and HER2- early stage invasive ductal carcinoma who underwent preoperative breast MRI, oncotype risk scoring, and breast conservation surgery from 2008-2010 were identified. After registration, BPE from the pre and three post-contrast phases was automatically extracted using a k-means clustering algorithm. Four metrics were calculated: initial enhancement (IE) relative to the pre-contrast signal, late enhancement, overall enhancement (OE), and area under the enhancement curve (AUC). Histogram analysis was performed to determine first order metrics which were compared to oncotype risk score groups using Mann-Whitney tests and Spearman rank correlation analysis. RESULTS: This study included 80 women (mean age = 51.1 ± 10.3 years); 46 women were categorized as low risk (≤17) and 34 women were categorized as intermediate/high risk (≥18) according to Oncotype Dx. For the mean of the top 10% pixels, significant differences were noted for IE (p = 0.032), OE (p = 0.049), and AUC (p = 0.044). Using the risk score as a continuous variable, correlation analysis revealed a weak but significant correlation with the mean of the top 10% pixels for IE (r = 0.26, p = 0.02), OE (r = 0.25, p = 0.02), and AUC (r = 0.27, p = 0.02). CONCLUSION: BPE metrics of enhancement in the non-tumor breast are associated with tumor Oncotype Dx recurrence score, suggesting that the breast microenvironment may relate to likelihood of recurrence and magnitude of chemotherapy benefit.

4.
Eur Radiol ; 30(2): 756-766, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31468162

RESUMO

OBJECTIVES: This study aims to evaluate ultrafast DCE-MRI-derived kinetic parameters that reflect contrast agent inflow effects in differentiating between subcentimeter BI-RADS 4-5 breast carcinomas and benign lesions. METHODS: We retrospectively reviewed consecutive 3-T MRI performed from February to October 2017, during which ultrafast DCE-MRI was performed as part of a hybrid clinical protocol with conventional DCE-MRI. In total, 301 female patients with 369 biopsy-proven breast lesions were included. Ultrafast DCE-MRI was acquired continuously over approximately 60 s (temporal resolution, 2.7-7.1 s/phase) starting simultaneously with the start of contrast injection. Four ultrafast DCE-MRI-derived kinetic parameters (maximum slope [MS], contrast enhancement ratio [CER], bolus arrival time [BAT], and initial area under gadolinium contrast agent concentration [IAUGC]) and one conventional DCE-MRI-derived kinetic parameter (signal enhancement ratio [SER]) were calculated for each lesion. Wilcoxon rank sum test or Fisher's exact test was performed to compare kinetic parameters, volume, diameter, age, and BI-RADS morphological descriptors between subcentimeter carcinomas and benign lesions. Univariate/multivariate logistic regression analyses were performed to determine predictive parameters for subcentimeter carcinomas. RESULTS: In total, 125 lesions (26 carcinomas and 99 benign lesions) were identified as BI-RADS 4-5 subcentimeter lesions. Subcentimeter carcinomas demonstrated significantly larger MS and SER and shorter BAT than benign lesions (p = 0.0117, 0.0046, and 0.0102, respectively). MS, BAT, and age were determined as significantly predictive for subcentimeter carcinoma (p = 0.0208, 0.0023, and < 0.0001, respectively). CONCLUSIONS: Ultrafast DCE-MRI-derived kinetic parameters may be useful in differentiating subcentimeter BI-RADS 4 and 5 carcinomas from benign lesions. KEY POINTS: • Ultrafast DCE-MRI can generate kinetic parameters, effectively differentiating breast carcinomas from benign lesions. • Subcentimeter carcinomas demonstrated significantly larger maximum slope and shorter bolus arrival time than benign lesions. • Maximum slope and bolus arrival time contribute to better management of suspicious subcentimeter breast lesions.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Meios de Contraste , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/patologia , Diagnóstico Diferencial , Feminino , Humanos , Cinética , Pessoa de Meia-Idade , Estudos Retrospectivos
5.
J Magn Reson Imaging ; 50(5): 1468-1477, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-30916835

RESUMO

BACKGROUND: Small breast lesions are difficult to visually categorize due to the inherent lack of morphological and kinetic detail. PURPOSE: To assess the efficacy of radiomics analysis in discriminating small benign and malignant lesions utilizing model free parameter maps. STUDY TYPE: Retrospective, single center. POPULATION: In all, 149 patients, with a total of 165 lesions scored as BI-RADS 4 or 5 on MRI, with an enhancing volume of <0.52 cm3 . FIELD STRENGTH/SEQUENCE: Higher spatial resolution T1 -weighted dynamic contrast-enhanced imaging with a temporal resolution of ~90 seconds performed at 3.0T. ASSESSMENT: Parameter maps reflecting initial enhancement, overall enhancement, area under the enhancement curve, and washout were generated. Heterogeneity measures based on first-order statistics, gray level co-occurrence matrices, run length matrices, size zone matrices, and neighborhood gray tone difference matrices were calculated. Data were split into a training dataset (~75% of cases) and a test dataset (~25% of cases). STATISTICAL TESTS: Comparison of medians was assessed using the nonparametric Mann-Whitney U-test. The Spearman rank correlation coefficient was utilized to determine significant correlations between individual features. Finally, a support vector machine was employed to build multiparametric predictive models. RESULTS: Univariate analysis revealed significant differences between benign and malignant lesions for 58/133 calculated features (P < 0.05). Support vector machine analysis resulted in areas under the curve (AUCs) ranging from 0.75-0.81. High negative (>89%) and positive predictive values (>83%) were found for all models. DATA CONCLUSION: Radiomics analysis of small contrast-enhancing breast lesions is of value. Texture features calculated from later timepoints on the enhancement curve appear to offer limited additional value when compared with features determined from initial enhancement for this patient cohort. LEVEL OF EVIDENCE: 4 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:1468-1477.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Adulto , Idoso , Algoritmos , Feminino , Humanos , Cinética , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Máquina de Vetores de Suporte , Adulto Jovem
6.
Sci Rep ; 8(1): 4838, 2018 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-29556054

RESUMO

We present a segmentation approach that combines GrowCut (GC) with cancer-specific multi-parametric Gaussian Mixture Model (GCGMM) to produce accurate and reproducible segmentations. We evaluated GCGMM using a retrospectively collected 75 invasive ductal carcinoma with ERPR+ HER2- (n = 15), triple negative (TN) (n = 9), and ER-HER2+ (n = 57) cancers with variable presentation (mass and non-mass enhancement) and background parenchymal enhancement (mild and marked). Expert delineated manual contours were used to assess the segmentation performance using Dice coefficient (DSC), mean surface distance (mSD), Hausdorff distance, and volume ratio (VR). GCGMM segmentations were significantly more accurate than GrowCut (GC) and fuzzy c-means clustering (FCM). GCGMM's segmentations and the texture features computed from those segmentations were the most reproducible compared with manual delineations and other analyzed segmentation methods. Finally, random forest (RF) classifier trained with leave-one-out cross-validation using features extracted from GCGMM segmentation resulted in the best accuracy for ER-HER2+ vs. ERPR+/TN (GCGMM 0.95, expert 0.95, GC 0.90, FCM 0.92) and for ERPR + HER2- vs. TN (GCGMM 0.92, expert 0.91, GC 0.77, FCM 0.83).


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Algoritmos , Automação , Estudos de Viabilidade , Feminino , Humanos , Estudos Retrospectivos
7.
AJR Am J Roentgenol ; 207(3): 592-8, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27352026

RESUMO

OBJECTIVE: The objective of our study was to evaluate the role of a hybrid T2-weighted imaging-DWI sequence for prostate cancer diagnosis and differentiation of aggressive prostate cancer from nonaggressive prostate cancer. MATERIALS AND METHODS: Twenty-one patients with prostate cancer who underwent preoperative 3-T MRI and prostatectomy were included in this study. Patients underwent a hybrid T2-weighted imaging-DWI examination consisting of DW images acquired with TEs of 47, 75, and 100 ms and b values of 0 and 750 s/mm(2). The apparent diffusion coefficient (ADC) and T2 were calculated for cancer and normal prostate ROIs at each TE and b value. Changes in ADC and T2 as a function of increasing the TE and b value, respectively, were analyzed. A new metric termed "PQ4" was defined as the percentage of voxels within an ROI that has increasing T2 with increasing b value and has decreasing ADC with increasing TE. RESULTS: ADC values were significantly higher in normal ROIs than in cancer ROIs at all TEs (p < 0.0001). With increasing TE, the mean ADC increased 3% in cancer ROIs and increased 12% in normal ROIs. T2 was significantly higher in normal ROIs than in cancer ROIs at both b values (p ≤ 0.0002). The mean T2 decreased with increasing b value in cancer ROIs (ΔT2 = -17 ms) and normal ROIs (ΔT2 = -52 ms). PQ4 clearly differentiated normal ROIs from prostate cancer ROIs (p = 0.0004) and showed significant correlation with Gleason score (ρ = 0.508, p < 0.0001). CONCLUSION: Hybrid MRI measures the response of ADC and T2 to changing TEs and b values, respectively. This approach shows promise for detecting prostate cancer and determining its aggressiveness noninvasively.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Idoso , Humanos , Masculino , Gradação de Tumores , Projetos Piloto , Prostatectomia , Neoplasias da Próstata/cirurgia
8.
Abdom Imaging ; 40(7): 2523-8, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25805558

RESUMO

PURPOSE: The purpose of the study is to determine short-term reproducibility of apparent diffusion coefficient (ADC) estimated from diffusion-weighted magnetic resonance (DW-MR) imaging of the prostate. METHODS: Fourteen patients with biopsy-proven prostate cancer were studied under an Institutional Review Board-approved protocol. Each patient underwent two, consecutive and identical DW-MR scans on a 3T system. ADC values were calculated from each scan and a deformable registration was performed to align corresponding images. The prostate and cancerous regions of interest (ROIs) were independently analyzed by two radiologists. The prostate volume was analyzed by sextant. Per-voxel absolute and relative percentage variations in ADC were compared between sextants. Per-voxel and per-ROI variations in ADC were calculated for cancerous ROIs. RESULTS: Per-voxel absolute difference in ADC in the prostate ranged from 0 to 1.60 × 10(-3) mm(2)/s (per-voxel relative difference 0% to 200%, mean 10.5%). Variation in ADC was largest in the posterior apex (0% to 200%, mean 11.6%). Difference in ADC variation between sextants was not statistically significant. Cancer ROIs' per-voxel variation in ADC ranged from 0.001 × 10(-3) to 0.841 × 10(-3) mm(2)/s (0% to 67.4%, mean 11.2%) and per-ROI variation ranged from 0 to 0.463 × 10(-3) mm(2)/s (mean 0.122 × 10(-3) mm(2)/s). CONCLUSIONS: Variation in ADC within the human prostate is reasonably small, and is on the order of 10%.


Assuntos
Imagem de Difusão por Ressonância Magnética , Interpretação de Imagem Assistida por Computador , Próstata/patologia , Neoplasias da Próstata/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Phys Med Biol ; 55(2): 389-401, 2010 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-20019403

RESUMO

Stereotactic radiosurgery delivers radiation with great spatial accuracy. To achieve sub-millimeter accuracy for intracranial SRS, a head ring is rigidly fixated to the skull to create a fixed reference. For some patients, the invasiveness of the ring can be highly uncomfortable and not well tolerated. In addition, placing and removing the ring requires special expertise from a neurosurgeon, and patient setup time for SRS can often be long. To reduce the invasiveness, hardware limitations and setup time, we are developing a system for performing accurate head positioning without the use of a head ring. The proposed method uses real-time 6D optical position feedback for turning on and off the treatment beam (gating) and guiding a motor-controlled 3D head motion compensation stage. The setup consists of a central control computer, an optical patient motion tracking system and a 3D motion compensation stage attached to the front of the LINAC couch. A styrofoam head cast was custom-built for patient support and was mounted on the compensation stage. The motion feedback of the markers was processed by the control computer, and the resulting motion of the target was calculated using a rigid body model. If the target deviated beyond a preset position of 0.2 mm, an automatic position correction was performed with stepper motors to adjust the head position via the couch mount motion platform. In the event the target deviated more than 1 mm, a safety relay switch was activated and the treatment beam was turned off. The feasibility of the concept was tested using five healthy volunteers. Head motion data were acquired with and without the use of motion compensation over treatment times of 15 min. On average, test subjects exceeded the 0.5 mm tolerance 86% of the time and the 1.0 mm tolerance 45% of the time without motion correction. With correction, this percentage was reduced to 5% and 2% for the 0.5 mm and 1.0 mm tolerances, respectively.


Assuntos
Movimentos da Cabeça , Monitorização Intraoperatória/métodos , Radiocirurgia/instrumentação , Radiocirurgia/métodos , Automação , Calibragem , Segurança de Equipamentos , Estudos de Viabilidade , Humanos , Movimento (Física) , Posicionamento do Paciente , Imagens de Fantasmas , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...